Dokuz Eylül University (DEU) measures the amount of low-carbon energy used across the university. Solar photovoltaic generation, geothermal heat and a small wind turbine are metered on every campus where they are installed. Total electricity and natural gas consumption is recorded building by building by certified energy managers and reported to the national Energy Efficiency Portal (ENVER). The results are published in the University’s annual greenhouse gas inventory and sustainability reports.

2. What is measured and how

2.1. Low-carbon energy sources in use

Source Location Capacity / basis How it is measured
Solar photovoltaic electricity Six campuses: Central (Tınaztepe), Dokuzçeşmeler, 15 Temmuz Health, Buca Faculty of Education, Institute of Marine Sciences and Technology, Torbalı Vocational School 15.2 MWe installed (project started March 2022) Generation meters at each plant; monthly generation records
Geothermal heat 15 Temmuz Health and Arts Campus (İnciraltı) Geothermal heat exchangers Monthly geothermal energy records (m³ and kWh)
Wind electricity Science and Technology Research and Application Centre (TEAM) Small rooftop turbine for night lighting Annual generation estimate

Waste vegetable oil from university kitchens (5,125 kg in May 2025–April 2026) is delivered to a licensed company and converted into biodiesel. The University does not use this biodiesel itself, so it is recorded but not counted as low-carbon energy used by the University. Forest-derived biomass is not used for energy on any campus.

2.2. Measurement of total energy use

Under the Energy Efficiency Law No. 5627, DEU has appointed certified energy managers for its campuses. Building Energy Managers record the annual electricity and natural gas consumption of each campus building in ENVER, the Energy Efficiency Portal of the Ministry of Energy and Natural Resources. Building automation systems monitor lighting, heating, cooling and ventilation in 17 smart buildings with about 236,000 m² of floor area (236,009 m² exact gross indoor area). All qualifying university buildings hold Energy Performance Certificates, and indoor temperatures are regulated at 21 °C during the heating season and 25 °C during the cooling season. In addition, comprehensive Energy Survey Reports prepared by an accredited energy audit company (İstanbul Enerji Sanayi ve Ticaret A.Ş., published November 2024, alongside earlier SETAŞ building audits) have assessed building automation, HVAC, pumping, lighting and insulation systems across eight campuses.

2.3. Reporting

  • Greenhouse gas inventory, calendar year 2025. The inventory covers 1 January to 31 December 2025 and was prepared on 19 January 2026 using the US EPA Simplified GHG Emissions Calculator. It reports Scope 1 (stationary combustion and mobile sources), Scope 2 (purchased electricity) and Scope 3 (waste). It is published on the Sustainability Office website.
  • Annual sustainability reports. The University’s annual sustainability reports are prepared in accordance with the UI GreenMetric reporting framework and cover the period from May of one year to April of the following year. Therefore, the energy data presented in the 2025–2026 Sustainability Report may differ from those reported for the 2025 calendar year (January–December 2025) due to differences in the reporting periods.
  • Public energy and climate page. The Sustainability Office maintains a page on the Green Campus website with the main renewable energy indicators.

3. Measured values

Indicator Sep 2024–Aug 2025 May 2025–Apr 2026 Calendar Year 2025 Unit
Low-carbon energy sources
Solar PV generation 24,658,977 24,110,405 24,219,130 kWh
Geothermal energy utilized 1,907,000 1,943,670 1,565,990 kWh
Wind electricity generation 913 913 913 kWh
Total low-carbon energy generation and utilization 26,566,890 26,054,988 25,786,033 kWh
Energy consumption
Electricity consumption (excluding hospital) 24,089,827 27,180,185 17,468,599 kWh
Natural gas consumption (excluding hospital) 21,265,160 21,968,037 17,447,010 kWh
Geothermal energy utilized 1,907,000 1,943,670 1,565,990 kWh
Total energy consumption (excluding hospital) 47,261,987 51,091,892 36,481,599 kWh
Low-carbon energy generation and utilization ratio (%) 56.2% 51.0% 70.7% %

Sources and scope note: DEU Sustainability Reports 2024–2025 and 2025–2026 (UI GreenMetric reporting periods) and metered ENVER, utility invoice, solar PV inverter, and geothermal heat records for calendar year 2025 (1 January–31 December 2025). Consistent with Indicators 13.2.2, 7.3.1 and 7.5.1, the DEU Research and Application Hospital (a regional tertiary healthcare facility with a 101,056 m² floor area and a distinct 24/7 clinical energy profile) is excluded from the campus energy consumption denominator, while all education, research and administrative facilities across campuses (719,993 m², including the Faculty of Medicine) are included. Solar PV generation (24,219,130 kWh in 2025) is integrated and accounted for through a grid-based electricity offsetting (mahsuplaşma) mechanism under national unlicensed electricity generation regulations.

4. Verification

Responsible units: Department of Construction and Technical Works (Energy Management Unit and building energy managers); Zero Waste and Environmental Management Coordination Office; Sustainability Office. Contact: greencampus@deu.edu.tr; yapiteknik@deu.edu.tr. Primary records: ENVER portal entries, monthly solar PV and geothermal generation meter records, utility invoices, and the 2025 greenhouse gas inventory. Last reviewed: 8 November 2026.

5. References

Dokuz Eylül University Sustainability Office. (2026). 2025 greenhouse gas emissions calculation (EPA Simplified GHG Emissions Calculator, reporting period 1 January–31 December 2025). https://greencampus.deu.edu.tr/wp-content/uploads/2026/01/2025-CO2.pdf

Dokuz Eylül University Sustainability Office. (n.d.). Enerji ve iklim değişikliği [Energy and climate change]. Retrieved October 21, 2026. https://greencampus.deu.edu.tr/tr/yesil-yerleske/enerji-ve-iklim-degisikligi/

Dokuz Eylül University. (2026). Dokuz Eylül University sustainability report 2025–2026. https://greencampus.deu.edu.tr/tr/surdurulebilirlik-hakkinda/deu-surdurulebilirlik-raporu/

Dokuz Eylül University Sustainability Office. (2024). Energy audit reports. https://greencampus.deu.edu.tr/wp-content/uploads/2024/11/EnergyAuditReports.pdf

Republic of Türkiye. (2007). Enerji Verimliliği Kanunu [Energy Efficiency Law] (Law No. 5627). https://www.mevzuat.gov.tr/mevzuat?MevzuatNo=5627&MevzuatTur=1&MevzuatTertip=5