THE question

Have water quality standards and guidelines for water discharges (to uphold water quality in order to protect ecosystems, wildlife, and human health and welfare).

Metric

15.4 Land sensitive waste disposal

2. Evidence Text for Publication

2.1. Statement

Dokuz Eylül University applies water quality standards to all wastewater discharged from its campuses: discharges must meet the limits of Türkiye’s Water Pollution Control Regulation and the sewer discharge standards of the İzmir Water and Sewerage Administration (İZSU); the University operates pre-treatment units to meet them and its Department of Environmental Engineering regularly analyses water and wastewater from the main discharge points.

2.2. Evidence

2.2.1. Standards applied

Regulatory Compliance: Campus wastewater is conveyed through institutional networks directly into the municipal sewerage infrastructure and treated at İZSU’s central advanced biological wastewater treatment plants.

National Discharge Standards: Effluent discharges strictly comply with the national standards set by the Water Pollution Control Regulation (Su Kirliliği Kontrolü Yönetmeliği, published in the Official Gazette on 31 December 2004, No. 25687).

Municipal Sewer Network Standards: Discharges conform to the parameter thresholds established under the İZSU Regulation on the Discharge of Wastewaters into the Sewerage Network (İZSU Genel Müdürlüğü Atıksuların Kanalizasyon Şebekesine Deşarj Yönetmeliği, enacted by İZSU General Assembly Decision on 15 May 2015, No. 04/10, as amended).

Effluent Pre-treatment: Kitchen and dining-hall effluents undergo mandatory physical pre-treatment (solids retention and fat/oil separation) to ensure that Biological Oxygen Demand (BOD₅), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), and Oil & Grease levels remain well below municipal sewer intake ceilings before entering public mains.

2.2.2. Pre-treatment on campus

  • Central Campus (Tınaztepe) Sedimentation Facility: A closed grit-chamber and sedimentation pre-treatment unit operates at the Central Campus, intercepting sand, heavy particulates, and suspended debris from primary campus collection branches. 

  • Grease Interceptor Systems: High-capacity automatic grease interceptors and oil separators at the Faculty of Medicine student cafeteria, central kitchen complexes, and the Central Campus social facilities cafeteria actively trap fats, oils, and grease (FOG), preventing sewer line blockages and downstream municipal treatment overload. 

  • 15 Temmuz Health and Arts Campus Pre-treatment Facility: A newly designed central pre-treatment and grease-retention facility servicing the integrated student dining halls and hospital catering facilities at the 15 Temmuz Health and Arts Campus was completed and commissioned in September 2025, modernizing effluent buffering across the medical and arts complex. 

2.2.3. Monitoring and laboratory controls

Systematic Sampling: Water and wastewater quality are monitored regularly at all major effluent generation and discharge junctions, specifically large dining halls, the Dokuz Eylül University Hospital clinical complex, central heating/cooling plants, and centralized laundry facilities.

Accredited Laboratory Analysis: Physical, chemical, and microbiological analyses are conducted by the Department of Environmental Engineering. The department’s Environmental and Wastewater Analysis Laboratory holds national TÜRKAK ISO/IEC 17025 laboratory accreditation and environmental measurement certification from the Ministry of Environment, Urbanisation and Climate Change. The accredited testing portfolio covers:

  • pH and Temperature 

  • Total Suspended Solids (TSS) 

  • Chemical Oxygen Demand (COD) & Biochemical Oxygen Demand (BOD₅) 

  • Oil and Grease (FOG) 

  • Heavy metal traces and microbiological indicators 

Rectorate Oversight: Analysis results and discharge compliance audits are compiled periodically and reported directly to the Rectorate and the Campus Environmental Safety Board.

Laboratory Hazardous Waste Segregation: Liquid chemical and biohazardous wastes generated in scientific and clinical laboratories are strictly barred from sewer lines. Under institutional safety guidelines, including the Department of Chemistry’s Chemical Hygiene Plan, chemical wastes are classified, stored in specialized UN-certified hazardous waste containers, and transferred to licensed disposal companies, strictly prohibiting the disposal of any chemical solvents, reagents, or toxic agents into drainage sinks.

2.2.4. Institutional framework and monitoring

Discharge control is part of the environment component of the Integrated Management System and is overseen by the Zero Waste and Environmental Management Coordinatorship.

The University’s Social Contribution Coordinatorship, established on 23 July 2024, coordinates the community-facing activities of all academic and administrative units under the Social Contribution and Sustainability Policy, with environment and sustainability as one of its thematic areas. These activities are monitored through the University’s integrated quality management system: the Integrated Management System Policy covers quality, environment, food safety and energy, and social contribution activities are recorded in the Quality Information System (KALBİS) and reviewed in the Plan–Do–Check–Act cycle. In 2025 the University recorded 5,925 public-facing events (panels, seminars, conferences), against a Strategic Plan target of 4,500 (target H3.3).

2.3. Verification

Responsible unit: Department of Construction and Technical Works. Contact: . Figures refer to calendar year 2025 unless otherwise stated; sources are the University’s 2025 Administrative Activity Report, the Sustainability Reports 2024–2025 and 2025–2026, and unit records.

2.4. Review Date

Last reviewed: Jan, 2026

3. References

Dokuz Eylül University Faculty of Science, Department of Chemistry. (2023). Kimyasal hijyen planı [Chemical hygiene plan]. https://kimya.deu.edu.tr/wp-content/uploads/2025/03/Kimya-Bolum-Hijyen-Plani.pdf

Dokuz Eylül University Sustainability Office. (2026). Dokuz Eylul University sustainability report 2025–2026. [https://greencampus.deu.edu.tr/wp-content/uploads/2026/07/DEU-SR-26.pdf

Dokuz Eylül University. (2026). 2025 yılı idare faaliyet raporu [2025 administrative activity report]. Strategy Development Department. https://strateji.deu.edu.tr/wp-content/uploads/2026/03/Dokuz-Eylul-Universitesi-2025-Yili-Idare-Faaliyet-Raporu.pdf

Su Kirliliği Kontrolü Yönetmeliği [Water Pollution Control Regulation]. (2004, December 31). Resmî Gazete [Official Gazette of the Republic of Türkiye], No. 25687.

Dokuz Eylül University Department of Chemistry. (2024). Laboratory safety rules, chemical waste management, and chemical hygiene plan. DEU Department of Chemistry.

Dokuz Eylül University Department of Environmental Engineering. (2025). Accredited environmental analysis, water, and wastewater testing laboratories. DEU Department of Environmental Engineering.

Dokuz Eylül University Quality Commission. (2022). Institutional self-evaluation report: Campus environmental infrastructure, water quality, and laboratory controls. Higher Education Quality Council of Türkiye (YÖKAK).

İzmir Water and Sewerage Administration [İZSU]. (2015, May 15). Regulation on the discharge of wastewaters into the sewerage network (General Assembly Decision No. 04/10). Republic of Türkiye Court of Accounts Audit Reports.

Republic of Türkiye Ministry of Environment and Forestry. (2004, December 31). Water pollution control regulation (Official Gazette No. 25687). T.C. Resmi Gazete.