7.2.3 Carbon reduction and emission reduction process


Dokuz Eylül University · THE Sustainability Impact Ratings 2027 · Evidence page

7.2.3 Carbon reduction and emission reduction process

Field Content
Indicator 7.2.3 Carbon reduction and emission reduction process
THE question Have a process for carbon management and reducing carbon dioxide emissions
Metric 7.2 University measures towards affordable and clean energy (SDG 7 Affordable and Clean Energy)

1. Statement

Dokuz Eylül University has a process for carbon management and reducing carbon dioxide emissions. The process has five steps that repeat every year: a policy commitment and long-term target, measurement of the carbon footprint, a reduction programme organised by emission scope, monitoring of energy data, and public reporting. It has been in operation since before 2025 and was applied throughout 2025.

2. The carbon management process

2.1. Step 1 – Commitment and target

  • DEU Sustainability and Climate Action Policy (April 2024): commits the University to focus on reducing greenhouse gas emissions and to develop strategies to measure, report and reduce its carbon footprint.
  • Net zero target: DEU has set 2049 as its target year for zero carbon emissions, with annual reductions of 25–30% targeted through renewable energy and efficiency measures. The target and the pathway are published on the Sustainability Office website.
  • Energy Efficiency, Clean Energy and Low-Carbon Campus Policy (published by the Sustainability Office in January 2026; reviewed October 2026): sets out the reduction of greenhouse gas emissions and a low-carbon campus as the core purpose of the University’s energy management, complementing the DEU Social Contribution and Sustainability Policy (Senate Decision No. 721/11, 30 December 2025).

2.2. Step 2 – Measurement

The Sustainability Office calculates the University’s greenhouse gas (GHG) emissions every year and publishes the results on the Green Campus portal and in the annual DEU Sustainability Report. For calendar year 2025 (1 January – 31 December 2025), the official institutional inventory was prepared on 19 January 2026 using the US EPA Simplified GHG Emissions Calculator in accordance with the Greenhouse Gas Protocol Corporate Standard (aligned with SDG 13 indicators 13.2.1, 13.2.2, 13.3.2, 13.4.1 and 13.4.2). This calendar-year 2025 inventory covers Scope 1 direct emissions of 3,894 t CO₂e—comprising 3,638 t CO₂e from stationary combustion of natural gas across campuses (21,718,799 kWh / 78,188 GJ) and 256 t CO₂e from mobile combustion across the 92-vehicle university fleet (with 0 t CO₂e fugitive refrigeration/AC leaks)—and Scope 2 location-based and market-based emissions of 12,501 t CO₂e from purchased grid electricity (36,274,083 kWh / 130,587 GJ), yielding a combined Scope 1 + Scope 2 total of 16,395 t CO₂e (0.263 t CO₂e per person across the campus population of 62,408 students and staff), plus partial Scope 3 waste emissions of 29 t CO₂e (total accounted emissions: 16,424 t CO₂e, with zero carbon offsets applied).

In addition to the calendar-year GHG Protocol inventory (16,395 t CO₂e Scope 1 + 2), the University calculates a supplementary UI GreenMetric carbon footprint for the academic reporting cycle (May 2025 – April 2026) covering purchased electricity (using an emission factor of 0.437 kg CO₂e/kWh) and on-campus transport (shuttles, cars and motorcycles using UK DEFRA 2025 conversion factors). For May 2025 – April 2026, this GreenMetric-scoped calculation equalled 12,052 t CO₂e, or 0.193 t CO₂e per member of the campus population (62,408 students and staff).

2.3. Step 3 – Reduction programme by scope

Scope / source Reduction measures in place in 2025
Scope 1 – stationary combustion (heating) Stationary natural gas combustion quantified at 3,638 t CO₂e in CY 2025 (21,718,799 kWh / 78,188 GJ across all campuses incl. hospital); geothermal heat exchangers at 15 Temmuz Health Campus supplied 1,565,990 kWh (5,638 GJ) in CY 2025 (1,943,670 kWh / 6,997 GJ in May 2025–Apr 2026); indoor temperature held at 21°C in the heating season since 2021; preventive maintenance of heating pipes, ducts, radiators and thermostatic valves; periodic sealing of doors and windows.
Scope 1 – mobile combustion Fleet mobile emissions quantified at 256 t CO₂e in CY 2025 (~179,512 kWh / 646 GJ across 92 university vehicles monitored via digital vehicle tracking system for route and fuel optimisation); electric vehicles used for patient transport at the University Hospital; 7 electric vehicle charging stations operating on campuses.
Scope 1 – fugitive emissions Regular maintenance and inspection of natural gas installations and air-conditioning units to prevent leaks; central air-conditioning run only when daytime temperature exceeds 28°C.
Scope 2 – purchased electricity Purchased electricity emissions quantified at 12,501 t CO₂e in CY 2025 (36,274,083 kWh / 130,587 GJ across all campuses incl. hospital). 15.2 MWe of solar PV capacity on 7 campuses generated 24,219,130 kWh (87,189 GJ) in calendar year 2025 and 24,110,405 kWh (86,797 GJ) in May 2025–April 2026 (88.7% of academic and administrative electricity use); cooling set-point of 25°C; LED lighting, motion sensors, inverter air conditioners and variable-speed pumps.
Scope 3 – waste, commuting and other Waste emissions quantified at 29 t CO₂e in CY 2025; Zero Waste Management System certified on 15 campuses (410,915 kg of inorganic waste collected separately for recovery in 2025–2026); free campus shuttle; public buses admitted onto the Central Campus; parking area cut from 86,900 m² to 40,000 m²; bicycle lanes and shared e-scooters. In addition, 3.1 million m² of campus forest is protected as a carbon sink (reported separately, not netted against emissions).

2.4. Step 4 – Monitoring

Building energy managers record the energy consumption of campus buildings in the national Energy Efficiency Portal (ENVER) of the Ministry of Energy and Natural Resources. Electricity, natural gas and water consumption are followed by the energy managers, and the Central Campus SCADA system was upgraded in 2025. DEU holds ISO 14001:2015 (environment) and ISO 50001:2018 (energy) certificates for the administrative services of the Rectorate within its Integrated Management System.

2.5. Step 5 – Reporting and review

Results are published in the annual GHG Inventory Report, the DEU Sustainability Report and on the Sustainability Office website. In 2026 the University also prepared its scientific and institutional contribution to the UNFCCC COP31 process (Antalya, 9–20 November 2026): under a Council of Higher Education (YÖK) call, DEU submitted 94 activities—of which 83 projects, workshops and international cooperation proposals were officially accepted by YÖK—under ten priority themes including Clean Energy Transition, Green Industrialisation, Climate-Resilient Cities and Climate Implementation Bridge. A Vice-Rector acts as DEU COP31 Coordinator.

3. Key figures

Item Value Period Source
GHG Protocol Scope 1 + Scope 2 emissions (official inventory) 16,395 t CO₂e (0.263 t/person) Calendar year 2025 2025 GHG Inventory (EPA Calculator, Jan 2026)
Scope 1 (stationary natural gas: 3,638 t; fleet: 256 t) & Scope 2 (electricity: 12,501 t) 3,894 t & 12,501 t CO₂e (+29 t Scope 3 waste) Calendar year 2025 2025 GHG Inventory (2025-CO2.pdf)
UI GreenMetric carbon footprint (electricity and campus transport) 12,052 t CO₂e (0.193 t/person) May 2025 – Apr 2026 DEU Sustainability Report 2025–2026
On-campus solar photovoltaic generation (15.2 MWe across 7 campuses) 24,219,130 kWh (87,189 GJ) ; 24,110,405 kWh in SR 25–26 Calendar year 2025 / May 25–Apr 26 ENVER / Meter Records & SR 2025–2026
Total low-carbon energy generated and used (solar, geothermal, wind) 25,786,033 kWh (92,830 GJ; 43.3% share) ; 26,054,988 kWh / 93,798 GJ in SR Calendar year 2025 / May 25–Apr 26 SDG 13 (13.2.1 & 13.2.2) / SR 2025–2026
Net zero target year (Scope 1 and Scope 2, zero offsets) 2049 (25–30% annual reduction pathway) 2019–2049 DEU Sustainability Office (13.4.1 & 13.4.2)

The 2024–2025 report used a different electricity emission factor (0.84 kg CO₂e/kWh); the two years are therefore not directly comparable and no reduction is claimed from that comparison.

4. Monitoring and verification

Implementation is monitored through the University’s Integrated Management System (quality, environment, food safety and energy) and the quality information system KALBİS, which records targets, actions and corrective actions in Plan-Do-Check-Act cycles. Results are published every year in the DEU Sustainability Report. The Social Contribution Coordination Office records the University’s climate and sustainability engagement with the public in the same quality system; in its 2025 report it identified 125 environment and sustainability activities delivered by 33 units between October 2024 and October 2025.

  • Responsible units: DEU Sustainability Office; Zero Waste and Environmental Management Coordination Office; Department of Construction and Technical Works (Energy Management Unit).
  • Contact: greencampus@deu.edu.tr; yapiteknik@deu.edu.tr
  • Policy / approval: DEU Rectorate Climate Action Plan Integration Decision (14 March 2019 / November 2021); DEU Sustainability and Climate Action Policy (April 2024); University Senate Decision No. 721/11 (30 December 2025); Energy Efficiency, Clean Energy and Low-Carbon Campus Policy (January 2026).
  • Last reviewed: 7 November 2026

5. References

Dokuz Eylül University Sustainability Office. (2024). Dokuz Eylül Üniversitesi sürdürülebilirlik ve iklim eylemi politikası [Sustainability and climate action policy]. https://greencampus.deu.edu.tr/wp-content/uploads/2024/04/DEU-Surdurulebilirlik-Politikasi.pdf

Dokuz Eylül University Sustainability Office. (2026a). Dokuz Eylül University sustainability report 2025–2026. https://greencampus.deu.edu.tr/about-sustainability/deu-sustainability-report

Dokuz Eylül University Sustainability Office. (n.d.). Net zero target. Retrieved October 21, 2026, from https://greencampus.deu.edu.tr/net-zero-target/

Dokuz Eylül University Sustainability Office. (2026b). Energy and climate change. Retrieved October 21, 2026, from https://greencampus.deu.edu.tr/tr/yesil-yerleske/enerji-ve-iklim-degisikligi/

Dokuz Eylül University. (2026, September 9). DEÜ, COP31’e bilimsel çalışmaları ve güçlü iş birlikleriyle hazırlanıyor [DEU prepares for COP31]. https://haber.deu.edu.tr/deu-cop31e-bilimsel-calismalari-ve-guclu-is-birlikleriyle-hazirlaniyor/

Dokuz Eylül University Social Contribution Coordination Office. (2025). 2025 yılı toplumsal katkı stratejik analiz ve faaliyet raporu [2025 social contribution strategic analysis and activity report]. https://toplumsalkatki.deu.edu.tr/wp-content/uploads/2026/01/DEU-2025-YILI-TOPLUMSAL-KATKI-RAPORU.pdf

Dokuz Eylül University Sustainability Office. (2026, January 19). 2025 greenhouse gas emissions calculation (EPA Simplified GHG Emissions Calculator, reporting period 1 January–31 December 2025). https://greencampus.deu.edu.tr/wp-content/uploads/2026/01/2025-CO2.pdf