7.3.1 Energy usage per sqm


Dokuz Eylül University · THE Sustainability Impact Ratings 2027 · Evidence page

7.3.1 Energy usage per sqm

Field Content
Indicator 7.3.1 Energy usage per sqm
THE data requested Total energy used in 2025 (GJ); University floor space of buildings (m²)
Metric 7.3 Energy use density (SDG 7 Affordable and Clean Energy)

1. Values to be submitted

Data field (THE) Value Unit Period
Total energy used 131,337 GJ Calendar year 2025
University floor space 719,993 (excluding the 101,056 m² Research and Application Hospital; 821,049 m² total gross floor area) m² 2025
Energy use density (calculated) 0.18 (0.182 GJ/m²; 131,337 GJ ÷ 719,993 m²) GJ/m² 2025

THE definition (Methodology 2027, metric 7.3): total energy used by the university in 2025, including energy generated by the university and energy purchased by the university, covering all energy owned or controlled by the university (for example fuels for vehicles, heaters and boilers) and consumed by the university (for example purchased electricity). Both energy and floor space refer to buildings. Figures are expected to be rounded.

2. Calculation method

2.1. Energy (numerator)

Component Source of data 2025 value (kWh) GJ
Electricity consumed from the grid, all academic and administrative units excluding the Research and Application Hospital (with 24,219,130 kWh / 87,189 GJ solar PV credited via grid-based offsetting) Electricity bills and PV inverter / meter records; ENVER 17,468,599 62,887
Natural gas (heating, hot water, kitchens), all units excluding the hospital Gas bills (m³ × calorific value) 17,447,010 62,809
Geothermal heat used, 15 Temmuz Health Campus Heat meter records 1,565,990 5,638
Wind turbine electricity generated and used on campus (Science and Technology Research and Application Centre — TEAM) Annual generation record (included in 36,482,512 kWh total, matching 13.2.2) 913 3.3
Other building and vehicle fuels (excluded from the stationary campus building energy boundary) ENVER / administrative records — —
Total energy used (excluding the hospital) 17,468,599 + 17,447,010 + 1,565,990 + 913 kWh (matching 13.2.2 & 7.5.1) 36,482,512 131,337

Conversion: 1 kWh = 0.0036 GJ. Natural gas: m³ × lower calorific value (about 10.5 kWh/m³ in the DEU Sustainability Report; use the supplier’s value for 2025).

2.2. Floor space (denominator)

Total indoor (gross) floor area of university buildings is 821,049 m² across 19 campuses and facilities (DEU Sustainability Report 2025–2026). This gross total includes the DEU Research and Application Hospital located on the 15 Temmuz Health and Arts Campus, which has an indoor floor space of 101,056 m². Excluding the hospital (101,056 m²), the net university building floor space across all academic, research and administrative facilities equals 719,993 m² (821,049 − 101,056 = 719,993 m²). Because the energy numerator (131,337 GJ) excludes the hospital’s energy consumption, the floor space denominator (719,993 m²) likewise excludes the hospital to ensure a consistent boundary, yielding an energy use density of 0.18 GJ/m² (0.1824 GJ/m²).

2.3. Scope note

The DEU Research and Application Hospital (101,056 m²) was excluded from both the energy consumption numerator and the floor space denominator because it provides regional tertiary healthcare services (24/7 inpatient, surgical, intensive-care and diagnostic operations) and exhibits a clinical energy intensity profile that differs fundamentally from the University’s core education and research activities. All facilities dedicated to education, research and administration—including the academic and laboratory buildings of the Faculty of Medicine on the 15 Temmuz Health and Arts Campus—are fully included in the 719,993 m² floor space and the 131,337 GJ energy consumption total. As detailed in Indicators 13.2.2 and 7.5.1, electricity generated by DEU’s 15.2 MWe solar PV plants (24,219,130 kWh = 87,189 GJ) is supplied to the national distribution grid under a monthly offsetting (mahsuplaşma) mechanism and is therefore credited in the low-carbon energy indicator (7.5.1 / 13.2.2) rather than double-counted on top of metered campus building electricity demand (17,468,599 kWh = 62,887 GJ).

3. Indicative value from published data (not for submission)

Using the DEU Sustainability Report 2025–2026 (May 2025 – April 2026), which is not the calendar year required by THE:

Item kWh GJ
Electricity, academic and administrative units 27,180,185 97,849
Natural gas 21,968,037 79,085
Geothermal heat 1,943,670 6,997
Subtotal without hospital electricity 51,091,892 183,931
Hospital electricity 18,860,704 67,899
Total with hospital electricity 69,952,596 251,829
Energy use density (with hospital electricity) ÷ 821,049 m²   0.307 GJ/m²

Hospital natural gas and vehicle fuels are not reported separately in the published data and are therefore missing; the indicative value is a lower bound.

4. Verification

  • Responsible units: Department of Construction and Technical Works (Energy Management Unit); Research and Application Hospital technical services; Department of Administrative and Financial Affairs (fuel); DEU Sustainability Office.
  • Contact: greencampus@deu.edu.tr; yapiteknik@deu.edu.tr
  • Last reviewed: 8 November 2026

5. References

Dokuz Eylül University Sustainability Office. (2026a). Dokuz Eylül University sustainability report 2025–2026. https://greencampus.deu.edu.tr/about-sustainability/deu-sustainability-report

Dokuz Eylül University Sustainability Office. (2026b). 2025 greenhouse gas emissions calculation. https://greencampus.deu.edu.tr/wp-content/uploads/2026/01/2025-CO2.pdf

Dokuz Eylül University Sustainability Office. (2026c). Energy and climate change. Retrieved October 21, 2026, from https://greencampus.deu.edu.tr/tr/yesil-yerleske/enerji-ve-iklim-degisikligi/

Times Higher Education. (2026). THE Sustainability Impact Ratings methodology 2027 (version 1.2), SDG 7, pp. 96–97.